Runtime problems¶
This page covers problems that appear while QubeSight is running: name resolution between containers, resource limits, certificate errors, a full disk, ClickHouse memory errors, Vector configuration reloads, cluster problems, the update channel, the language model and mail delivery. Each section gives the symptom, the cause and the fix.
Before you change anything, collect a support bundle.
Container name resolution (DNS)¶
Symptoms
- Service logs contain
lookup clickhouse … no such host(orredpanda,metadata-db). - Guardium health, alerts, dashboard rollups or the lifecycle stop working at the same time.
- Platform → System and Cluster → Status shows a red Name resolution failure: box above the component table.
Cause. Containers reach each other by service name. On hosts running Podman with the CNI network backend and the dnsname plugin, each container network has its own DNS server that knows only its own containers. A container attached to several networks (control plane, worker, gateway) asks all of them. When the host has an upstream DNS server configured, the "wrong" network's DNS server forwards the query upstream and returns "no such host", and resolution stops. Docker and Podman with the netavark backend are not affected.
What the product does. QubeSight's own services ask all configured DNS servers in parallel and use the first answer that contains records. When this compensation is active, the Status tab shows a blue Name resolution note: box; when names still cannot be resolved, it shows a red Name resolution failure: box. Both list the DNS servers in use. Tools that are not part of QubeSight (inside third-party containers) do not benefit from this.
Check:
The result is ok, compensated or broken. An optional service that is not installed is reported as absent, not broken.
Fix:
- On a fresh Podman host, the installer switches the host to
netavark/aardvark-dnsautomatically when it can (root, no existing containers, a host name server configured, packages installable). SetQUBESIGHT_PODMAN_KEEP_CNI=1to prevent this. - On an existing Podman CNI installation, do not add or change the host's upstream DNS configuration while it runs on CNI. If you already did and names stopped resolving, revert the change and restart each network's
dnsmasq(the DNS servers keep old upstreams until restarted), or restart the container engine in a maintenance window. Moving the host tonetavarkis the permanent fix; plan it for the next clean installation. - The fan-out can be turned off with
QUBESIGHT_DNS_FANOUT=off(not recommended).
Resource limits (ulimits)¶
Symptom. Redpanda or ClickHouse restarts with "too many open files", or Redpanda fails to start.
Cause. Redpanda needs a high open-file limit. The Compose file requests nofile 1,048,576 for Redpanda. If the container engine cannot grant it (for example a rootless engine or a systemd limit on the engine service), the container fails.
Fix. Run the container engine as root, or raise the engine service's LimitNOFILE (for example with a systemd drop-in for docker.service or podman.service), restart the engine in a maintenance window and start the stack again. Check the result with docker exec qubesight_redpanda sh -c 'ulimit -n'.
ClickHouse open-file limit on a single server¶
Symptom. On a single server, ClickHouse logs "too many open files" or refuses connections under load, typically on hosts with a recent container engine (for example Docker 29 or containerd 2).
Cause. These engines can give containers a default soft limit of 1,024 open files. ClickHouse opens many data-part files and connections and needs far more. Cluster nodes created by the product already requested a higher limit; the single-server Compose file did not before 2.0.107.
Fixed in 2.0.107. The single-server Compose file requests nofile 262,144 (soft and hard) for ClickHouse, the same value cluster nodes use.
What to do. Check the limit inside the container:
If it shows 1,024 and ClickHouse reports open-file errors: a server installed with 2.0.107 already has the higher limit. A server upgraded from an earlier release by a patch keeps its current ClickHouse container, because patches do not recreate ClickHouse; contact support to apply the 2.0.107 Compose setting in a maintenance window. If the engine cannot grant the higher limit (see above), raise the engine service's LimitNOFILE as described for Redpanda.
Repeated TLS messages on the witness or other Redpanda brokers¶
Symptom. In a cluster, the Redpanda log on the witness (or on any broker) shows a TLS connection that was "not properly terminated" about every 10 seconds.
Cause. In releases before 2.0.107 the control plane's topology probe opened a plain TCP connection to the broker's TLS-protected Kafka listener and closed it without a TLS handshake. The message is harmless: no data is affected.
Fixed in 2.0.107. The probe completes the TLS handshake and closes the connection properly, and the queue reader closes its connections. The messages stop once every node runs 2.0.107.
TLS and certificate errors¶
| Symptom | Cause | Fix |
|---|---|---|
| Browser warns about the certificate on every visit | The web certificate is self-signed or issued by the installation root, which the browser does not trust | Trust the installation root once per client, or upload a certificate from your CA. See Certificates. |
| "Connection to the server keeps dropping", "Failed to fetch", modules do not load | The browser rejects new TLS connections, typically right after the certificate changed | Reload the page; if the certificate changed, accept or trust the new one. Gateway logs show tls: unknown certificate from the client. |
| "{host} is not in the certificate" | You use an address the certificate does not cover (new DNS name, virtual IP) | Renew to cover this address for self-signed certificates, or reissue your CA certificate with the name. |
| The UI is unreachable after activating a new certificate | The new certificate does not cover the address, or clients do not trust its issuer | From another client that still works, use Return to the previous certificate; otherwise use the break-glass reset in Certificates. |
| Guardium unit shows an untrusted-certificate state | Guardium appliance certificates often do not contain the IP address used | Choose the Guardium certificate verification mode (verify with trusted certificates and pin the device certificate). See Guardium overview. |
| Senders refuse syslog TLS with "certificate has expired" | Ingest certificate expired; reconnecting clients refuse it | Reissue the ingest certificate; see Syslog and Kafka TLS. |
Disk full and the disk guard¶
Symptoms. "Disk full: incoming events on hold (N%)" or "Disk full: ClickHouse disk … at N%" alerts; dashboards stop updating; Retention → Disk status says "Incoming events are held (no loss)".
Cause. The ClickHouse disk reached the disk-guard threshold (default 90 %).
Fix:
- Do not delete files by hand inside ClickHouse or Redpanda directories.
- Check Platform → Data and Backup → Retention → Status and history: usage, oldest month, and what the guard is doing.
- Make room by one of: growing the disk; setting a retention period; enabling the hot/cold tier so older months move to the locked store; or, deliberately, switching the guard to Delete from the oldest, make room.
- Events wait in Redpanda while held. Make room within Redpanda's retention (7 days by default); Redpanda also grows on the same disk.
- Do not start a Guardium archive restore while the disk is full: restores bypass the guard.
Details: Data lifecycle and retention.
ClickHouse memory errors¶
Symptom. A report or dashboard shows a memory error (ClickHouse code 241, MEMORY_LIMIT_EXCEEDED).
Cause. The query needs more memory than ClickHouse allows. Product queries already adapt: read-only queries are retried automatically with less memory, more spilling to disk and fewer threads, and background jobs shrink their batches.
Fix:
- Narrow the time range or add filters and run the report again.
- If errors are frequent, check the ClickHouse container memory (
CLICKHOUSE_MEMORYin.env, sized at installation as a quarter of host RAM between 4 and 16 GiB) and the host's free memory. Increase it with the recommendation on Platform → System and Cluster → Capacity. - After a restore from backup, dashboard summaries are rebuilt and use more memory for a while; wait for the rebuild to finish.
Vector did not load its configuration¶
Symptom. Critical alert "Vector did not load its new configuration".
Cause. Vector did not answer on its metrics endpoint three minutes after its configuration was rewritten (for example after a pipeline policy change or an update). It may still run the previous configuration, without the disk buffer or the loss counter.
What the product does. It restarts Vector automatically (at most once per 10 minutes and three times in six hours, after a 90-second settle time).
Fix if it persists:
Look for Reload was not successful or failed to lock buffer.lock. On a cluster the alert is per node; restart Vector on the node named in the alert.
Cluster problems¶
Enterprise
| Symptom on the Cluster tab | Likely cause | Action |
|---|---|---|
| A node is unreachable | Server down, network split or SSH failure | Check the server. If it is down, the cluster continues on the remaining majority; bring it back as described in Cluster operations. |
| Two nodes unreachable in a three-vote cluster | Majority lost: Keeper, etcd and Redpanda stop accepting writes | Restore at least one node quickly. Events held at senders or in Vector's disk buffer are written when the majority returns. |
| No PostgreSQL leader, or no synchronous replica | Patroni cannot reach etcd or its peers | Check etcd members and network between nodes; Patroni keeps the leader while it sees all members even if etcd is unreachable. |
| Log topic with fewer than 3 replicas while 3 brokers run | A join did not finish raising replication | The Cluster tab and a critical Platform component alert show it. Re-run the join or contact support. |
| Job shows interrupted | The control plane restarted during a cluster job | The source node marks stale jobs; start the job again. Leftovers can be listed with -cluster-orphans. |
| A node keeps a different version | Automatic node update failed and is retried after an hour | Click Update on the node row and read the job detail. |
| A cluster operation is refused after you enter Your administrator password | Wrong password; five wrong passwords within 15 minutes (further attempts are refused until the oldest of them is more than 15 minutes old); the account is locked by the password policy; or you are signed in with an SSO or LDAP account, which has no local password | Wait and retry with the correct password, or sign in with a local administrator account. See Cluster operations. |
Update channel unreachable¶
Symptom. On Update → Automatic updates, "The update channel could not be reached (network, DNS, firewall or proxy)"; after three days a medium Automatic updates alert.
Check:
- The control plane can resolve
updates.qubesight.io(on Podman CNI hosts see Container name resolution). - The firewall allows outbound TCP 443 to that name.
- The proxy settings under Advanced (address, proxy, root CA, pinning), or the
HTTPS_PROXYenvironment variable of the control plane. - With a TLS-inspecting proxy, its root certificate in Extra root certificate.
- The server clock: "The manifest appears to be issued in the future" or "The manifest has expired" can also mean a wrong clock.
Nothing is changed on the system while the channel is unreachable; checks are retried every 30 minutes. In an isolated network, apply patches manually instead.
Assistant or language model unavailable¶
Symptoms. "The assistant server is not reachable. See the assistant card in Settings → Assistant."; natural-language report creation or the daily briefing does not work.
Check on Platform → Settings → Assistant:
- The local assistant card shows Running, Sleeping (the model is unloaded when idle and reloads on the next question, which takes a few seconds) or Not reachable.
- Model file on this node: if missing, click Download the model. The download needs outbound internet access; in an air-gapped installation the model must come with the offline bundle.
- The local assistant is installed by default only on servers with enough memory and CPU; on smaller servers it may not be installed at all.
- For a large-model provider, use the provider's Test; errors show the provider's reason (wrong key, quota, DNS, TLS). Outbound access to the provider is required.
On a cluster, each full node uses its own assistant first and falls back to a peer's. See LLM providers.
Mail delivery failures¶
Symptoms. Alert e-mails do not arrive; the Notification channel problem alert is open.
Check:
- Platform → Settings → Notifications: the shared SMTP server, port, security mode, sender and credentials. Use the channel's Test button; "Test notification sent" means the server accepted the message.
- Assurance Center → Alerts & Notifications → Delivery queue: failed notifications with the server's error. Failed deliveries are retried with growing intervals; abandoned ones can be retried from there.
- Network: outbound access from the server (or, on a cluster with egress through the virtual IP, from the virtual IP) to the mail server port.
- If the mail server uses a private CA, the certificate must be trusted.
- If no channel is enabled, the No notification channel alert is open and alerts reach nobody.