Monitoring and health¶
This page explains how QubeSight monitors itself: the component status screen, the platform health alerts, source silence detection, the log-loss counter and the drift alarms, and how to route them to your operations team.
Community Enterprise
Component status and platform alerts are in both editions. Source Health (the source-silence watchdog) and the cluster health summary are Enterprise only.
Where to look¶
| Screen | What it shows | Who sees it |
|---|---|---|
| Platform → System and Cluster → Status | Live probe of every platform component; the cluster health summary when a cluster exists | admin, analyst, dba, auditor |
| Data Sources → Source Health | Per-source silence status and the dead man's switch | admin, analyst, dba, auditor (Enterprise) |
| Assurance Center → Alerts & Notifications | Open alerts, including all platform health alerts | admin, analyst, dba, auditor |
| Pipeline → Flow | What was stored and not stored, and the red Log loss notice | admin and roles with pipeline access |
| Platform → System and Cluster → Service logs | Live container logs and the support bundle | Live logs: admin, analyst, dba (the auditor sees the tab but is refused the logs). Support bundle: admin only. |
Component status¶
Platform → System and Cluster → Status probes the platform components regularly and refreshes every 30 seconds. The same probe results feed the health alerts, so what you see here is what triggers notifications.
- Counters: Components, Up, Down, Critical down.
- Platform components table: component, kind, endpoint, zone, role, up/down, latency, detail and the time it was checked. Critical components are marked with
*. - In a cluster (Enterprise, for roles that can see the Cluster tab), a one-line summary ("Cluster is healthy" or "{n} cluster problem(s)", with Keeper votes, Settings database members, Queue brokers and up to three problems) links to the Cluster tab through Cluster details.
- If container name resolution is impaired (for example the podman CNI split-DNS condition), a banner appears above the table: blue when the product compensates for it, red when names cannot be resolved. See Runtime problems.

Health probes for external monitoring¶
The control plane exposes unauthenticated health probes that a load balancer or monitoring system can poll:
| Path | Meaning |
|---|---|
/healthz |
The process is alive; also reports the running version. |
/readyz |
Ready to serve: the settings database, ClickHouse and the worker are reachable. Returns not-ready when PostgreSQL is configured but unavailable. |
The probes are served on the API port (8085 by default, bound to 127.0.0.1 on a standard installation). The gateway also answers /_qs/healthz. The product does not publish a Prometheus metrics endpoint for its own services in this release.
Platform health alerts¶
Built-in alert rules in the Platform, Backup and Integrity categories watch the platform. They are evaluated continuously, open an alert in Assurance Center → Alerts & Notifications and are delivered through your notification channels. Each alert closes by itself when the condition clears.
| Rule (kind) | Opens when | Typical title |
|---|---|---|
| Platform component | A probed component is unreachable or not running; a log topic has fewer than 3 replicas while 3 brokers run (cluster); Vector discarded events it could not write to Kafka; Vector did not load its new configuration | "Component unreachable: …", "Log loss: …" |
| Disk usage | A ClickHouse disk is above 85 % (rule parameter) | "Disk full: ClickHouse disk … at N%" |
| Disk protection | Events are held or dropped by the disk guard, or it deleted data in the last 24 hours | "Disk full: incoming events on hold (N%)" |
| Pre-aggregation lag | Dashboard summaries fall behind | "Dashboard pre-aggregation layer lagging" |
| Backup overdue / Backup failed | The last successful backup is older than the RPO target, or a run failed; also when scheduled backups are disabled | "Backup overdue: …" |
| Restore drill | The last restore drill failed, or is older than twice the rehearsal interval | "Restore drill overdue" |
| Restore failure | Guardium archive restore errors | "Restore errors: N files…" |
| Locked store | Export to the locked store fails or lags, the store is unreachable, its lock is weaker than expected, or data differs from the locked copy | "Export to the locked store failing" |
| Notification channel problem / No notification channel | A channel fails, or no channel is enabled | "No enabled notification channel" |
| Self-audit writes / Self-audit forwarding | Audit records cannot be written or forwarding to SIEM lags | "Self-audit records cannot be written" |
| Automatic updates (Enterprise) | An automatic update failed (high), the channel could not be checked for 3 days or its manifest is invalid (medium), a version is waiting under Notify only or Download (low) | "Automatic update failed: …" |
| Scan failed / Log discovery failed | A sensitive-data scan or log discovery run failed | "Sensitive data scan failed: …" |
Make sure at least one notification channel is enabled, otherwise platform alerts reach nobody (the No notification channel alert tells you). Channels are configured under Platform → Settings → Notifications; see Mail (SMTP) and notification channels.
Source silence (dead man's switch)¶
Enterprise
A source that stops sending is often the first sign of a broken audit configuration. Data Sources → Source Health learns each source's normal rhythm and raises Source silence ("Log source silent: …") when a source has been quiet for longer than expected:
- For a regular source, the expected maximum silence is the larger of 60 minutes and three times (its 95th-percentile gap + 60 minutes), learned from the last 14 days. Gaps are measured in whole hours, so a regular source is never flagged as silent before 360 minutes (6 hours).
- A sparse source (active in fewer than 6 hours of the period) is allowed 24 hours of silence.
- Sources that only came from a one-time archive restore are not expected to keep sending.
See Source Health for the screen.
Log loss and drift¶
- Log loss. Vector keeps pending events in a disk buffer and retries Kafka indefinitely. If it has to discard an event because Kafka refuses it permanently (message size, authorisation), the workers count it: Pipeline → Flow shows "Log loss: N event(s) were discarded without being written to Kafka" and a critical Platform component alert opens. In a correctly configured installation the counter stays at zero.
- Vector configuration not loaded. If Vector does not load a new configuration within three minutes, a critical per-node alert opens and Vector is restarted automatically (at most once every 10 minutes and three times in six hours).
- Image drift. If a QubeSight container runs a different image than the installed release, or a cluster node's compose file differs from its running containers, a per-node alert opens. See Upgrades.
Daily routine¶
- Check Status for components that are down.
- Check open alerts in the Platform, Backup and Integrity categories.
- Check Source Health for silent sources (Enterprise).
- Weekly: check Data and Backup → Backup for the last successful backup and Retention → Status and history for disk usage.
Limitations¶
- The product does not show Kafka consumer lag directly. A backlog appears as delayed data on screens and, if it persists, as pre-aggregation lag.
- There is no certificate-expiry alert; see Certificates and key rotation.
- There is no fast pipeline-wide "no events at all" alert. Source silence detects a silent source after its learned threshold, typically in hours.